bitte wählen
- Analoge Messtechnik
- Stromwandler
- Analogue Meters
- Nebenwiderstände / Shunts
- Digitale Messtechnik
- Energiemanagement
- Digital meters
- Energy Management
- Shunts
-
Current transformers
- XCTB current transformer - measuring at up to 20 kHz
- Tube current transformer ASK
- Compensation current transformer CCT
- Tube current transformer CTM 7
- Differential current transformer type A, series DACT
- Split core current transformer KBR
- Split core current transformer KBU
- Current transformer CTB
- Rogowski-coil current transformers FASK
- 3-Phase Power Measuring System "Quick Connect"
- Messumformer
- Transducers
- Stromschienen-Isolatoren und -Halter
- Bus bar insulators and supports
- Gas warning systems
- Gaswarnsysteme
- Laboratory & teaching aids
- Labor & Lehrmittel
Rogowski-coil current transformers FASK
- Flexible current transformers with divisible measuring system
- Rogowski-coil current transformers FASK
The flexible Rogowski-coil transformers of the type FASK have been designed for accurate measurements over a wide range of alternating current, pulsating direct current or distorted current signals.
They can be used for alternating current measurement with a high dynamic range and frequency range from 10Hz to 20kHz.
NEW: now also available for output x/1 A.
- • Loop diameters from 35 mm to 305 mm
- • By the flexible and very thin design of the coils, these can be easily guided around the current conducting conductor and plugged together
- • Simple, fast and non-interrupting installation around current rails or cable bundles possible
- • Ideal for applications with very little available space
- • Very low conductor position sensitivity
- • No danger with open output circuit
• Operating temperature: -30°C to +60°C
• Storage temperature: -40°C to +60°C
• Insulation category: CAT III 1000 V / CAT IV 600 V (PD2 double insulated)
• Safety standards: EN/UL/cUL 61010-1, 61010-2-032
• Testing voltage: 7400 V / 1 min
• Linearity: ± 0,2% (at 10-100% of nominal value)
• Conductor position sensitivity: ± 2% max. (± 1% max. for type „I“)
• Influence of external fields: ± 2% max. (± 1,5% max. for type „I“)
• Storage temperature: -40°C to +60°C
• Insulation category: CAT III 1000 V / CAT IV 600 V (PD2 double insulated)
• Safety standards: EN/UL/cUL 61010-1, 61010-2-032
• Testing voltage: 7400 V / 1 min
• Linearity: ± 0,2% (at 10-100% of nominal value)
• Conductor position sensitivity: ± 2% max. (± 1% max. for type „I“)
• Influence of external fields: ± 2% max. (± 1,5% max. for type „I“)
-
Rogowski-coil transformers FASK
Dateityp: pdfDateigrösse: 2.37 MBInfo: Currently available in German only - for questions please contact us by phone or email. - Datei herunterladen